Operating job computer on the field
Tank filling
Filling up the tank with TANK-Control and fill stop
If a TANK-Control with fill stop has been installed and configured on the field sprayer, you can use it.
It will stop tank filling automatically when a specified fill level is reached.
You can define up to two refill limits for tank filling. The system stops filling the tank when the tank
content reaches these refill limits.
Open ball valve for tank filling
- Ball valve opens.
- The following icon will appear on the
screen:
- Water is being pumped.
- Current tank content changes slowly.
Close ball valve for tank filling
Change active refill limit
Only the refill limit selected is taken into
account while filling the tank. The tank is
filled until the fill level is reached.
To fill the tank with two refilling limits:
TANK-Control with fill stop is installed on the field sprayer.
1. Switch to the "Tank filling - TANK-Control" screen:
⇨ The following screen appears:
2. For Refilling limit 1 and 2, you can enter up to two fill levels at which the filling pump should be
stopped or the filling ball valve should be closed.
⇨ If you enter two refilling limits, a new function icon appears on the screen:
⇨ Press the icon to mark a refilling limit at which the pump should be stopped.