Configuring the job computer
Configuring sections
Permanently switched off sections are marked in white on the work screen
1. Switch to the "BOOM" screen:
>
⇨ The "BOOM" screen appears.
2. - Press.
⇨ The "SECTIONS" screen appears.
⇨ For each section, you can see one of the following icons:
- Section activated
- Section deactivated.
3. For each section, you can select and change this icon.
Permanently switching off a section using a sensor
If a sensor for monitoring the unfolding of boom sections is installed on the boom, sections can be
automatically permanently switched off.
This enables the use of a field sprayer with multiple working widths without having to change the
configuration each time.
System delay when switching the sections
For SECTION-Control to be able to open and close the section valves precisely, you must determine
how many milliseconds are required for the liquid to travel from the valve to the nozzle. Afterwards,
the job computer will switch the valves earlier or later accordingly.
Delay on start
Time that elapses between the opening of a section valve and the emergence of liquid out of the
nozzles.
Rule of thumb:
▪ If the sprayer switches too late, increase the value of the parameter.
▪ If the sprayer switches too early, decrease the value of the parameter.
Delay on Stop
Time during which the nozzles continue spraying after the valve has been closed.
Rule of thumb:
▪ If the sprayer switches too late, increase the value of the parameter.
▪ If the sprayer switches too early, decrease the value of the parameter.
You are using the automatic SECTION-Control.