Configuring the job computer
Configuring the nozzles - for field sprayers with pressure sensor regulation
The sections are not closed when the application rate is 0 l/ha.
Everything is recorded in the process.
The sections are closed when the application rate is 0 l/ha.
Only the applied areas are recorded.
The sections are closed when the application rate is 0 l/ha.
Both the applied areas and areas where nothing was applied will be
recorded.
This is the standard setting when using SECTION-Control.
Configuring the nozzles - for field sprayers with pressure sensor
regulation
By configuring the nozzle type, the job computer can calculate the current application rate based on
the measured spray pressure.
You only have to configure the nozzles if a pressure sensor is installed on the field sprayer.
If no pressure sensor is installed on the field sprayer and the application rate is regulated only
through the flow rate, then you do not need to configure the nozzles.
Nozzle assistant
The nozzle assistant serves the following purposes:
▪ To show how the nozzle type affects the possible application rates and speeds.
▪ To help with the correct selection of the installed nozzle type.
▪ To change the target rate.
Changes the calculated data
Determination of possible application rates