Chapter 3 – Installing Software
28 MultiVOIP® Voice/Fax over IP Gateways
b. Complete Disconnect fields:
Current Reversal (use current reversal to disconnect)
Current Loss (loss of current triggers disconnect)
Current Loss Timer (time after current loss to disconnect; in milliseconds)
Silence Detection Enable (use silence detection to disconnect)
Silence Detection Type (one-way or two-way)
Silence Timer (time of silence needed to trigger disconnect; in seconds)
DTMF Tone (use tones to disconnect)
Disconnect Tone Sequence (select tone pairs to use for disconnecting)
Tone Detection (disconnect from termination of tone)
Available Tones
Disconnect Tones (shows current selection from Available Tones)
12. In the E&M Options group (not supported by –SS and –FX series):
In the Signal group, select Dial Tone or Wink.
In Wink Timer field, type a type, whose range can be 100 to 350 milliseconds; default is 250.
From the Type drop-down list, select TYPE 1 or TYPE 11.
In the Mode group select 2-wire or 4-wire.
In the No Response Timer field type the time, in seconds, after which an FXO call is disconnected.
Check Disconnect on Call Progress Tone if you want to disconnect when PBX issues call progress tone.
13. In the Pass Through Options group select Enable to create an open audio patch; not for use with Wink
signaling.
14. In the DID Options group: (not supported by –SS and –FX series)
From Start Modes drop-down list, select Immediate, Wink or Delay Dial.
In the Wink Timer field type time, in milliseconds.