Operation
Betriebsanleitung 07.06.2005 21/43
ba_c500_50s2GB06.fm ega
Close lid, wait until the end of the cycle, remove pouch
Close lid and press down until it is held down by the vacuum generat-
ed.
The following processes function automatically:
The vacuum pump starts.
The lid is sucked down until it is fixed in place.
The air is sucked out of the chamber and pouch.
Visible in the digital display: the pressure decreases.
If pre-set values for
pressure (e.g., 20 mbar),
lowest possible residual pressure in the "Auto" function,
post-evacuation time x (if desired) are reached, the pouch is sealed.
The sealing bar is pressed against the pouch, the wires on the sealing
bar are heated up for the set sealing time.
The pouch is sealed.
The chamber is ventilated.
Visible in the digital display: the pressure increases.
The lid opens and swings up!
Example:
Diagram pressure/time curve
0
100
200
300
400
500
600
700
800
900
1000
Adjustable pressure
20 mbar
Pressure
5 mbar
t
mbar
p
s
x