Trouble-shooting
Betriebsanleitung 07.06.2005 36/43
ba_c500_50s2GB06.fm ega
Trouble-shooting
Poor vacuum or poor sealing could result from incorrectly set settings (un-
intended).
Always note:
If a program key is pressed longer than approx. 3 seconds, the saved set-
tings are over-written.
Problem Cause Solution
Machine is not running. Machine is switched off. Switch on
Power supply was interrupted. Switch on
Plug is not plugged in. Plug in the plug.
Lid does not keep
closed despite running
pump.
Lid is not completed closed or is
pressed shut too quickly.
Press the lid shut more firmly
and for a longer period of time.
Lid seal is dirty. Clean lid seal.
Lid seal is damaged. Replace lid seal.
Lid is misadjusted. Adjust lid.
Sealing leaks or oth-
erwise not ok – pouch is
slack
Too little pressure:
Set values are improper.
Incorrect program is chosen.
Correct the settings.
Sealing time is set incorrectly. Correct the sealing time.
Pouch is unsuitable. Use pouch capable of being
sealed.
The pouch neck is squeezed by
the lid.
Insert the pouch so that the
pouch neck is within the cham-
ber.
Sealing force is insufficient. Check settings. Sufficient seal-
ing force can only be obtained
when the pressure is under 400
mbar.
The Teflon strip or sealing wire
on the sealing bar is damaged.
Replacement --> See the "As-
sembly instructions for the
sealing equipment repair kit".
Pouch leaks. Use a new pouch.
Seal seam is dirty. Keep clean.