Care and maintenance
Betriebsanleitung 07.06.2005 31/43
ba_c500_50s2GB06.fm ega
Care and maintenance
Maintenance recommendations
Note
If it is necessary that the pressure is maintained exactly, the built-in pres-
sure sensor should be calibrated yearly. To do this, please contact the
customer service.
The following work is for
normal conditions of
use. The intervals spec-
ified must be shortened
accordingly given ag-
gravated conditions
(products with high per-
centage water, liquids,
and longer daily work-
ing hours).
Before starting to work
After finishing work, or daily
Weekly
Monthly
annually
For faults
As necessary
For damage
See appendix
Complete machine Visual inspection (con-
dition)
X
Cleaning XX
Lid seal Check (wear, damage) XXX
Teflon strip, sealing bar Check (wear, damage) XXXX
Sealing equipment Check sealing and sep-
arating wire
XXXX
Connecting cable Inspect, replace by
trained electrician
XX
Vacuum pump Check the oil level and
top it up if necessary
XX
Vacuum sensor Replace filter in the
measuring lines
X
Tension springs
Chamber lid
Check the tension
springs for spring
breakage.
)tension springs may
only be replaced by the
MULTIVAC service or-
ganisation).
X