© Munters AB, 2020 74
7.13
Feeding Devices
Setting up a feed system requires auger relays and sensors, and feeder relays and sensors. Define:
•
Auger and feed relays to control the auger/feeder lines.
•
Auger digital sensors to detect auger overtime issues: silo is empty, feed lines are stuck, or other
mechanical issue.
o
Auger 1 is automatically associated with Augur Active Sensor 1. Auger 2 is
automatically associated with Augur Active Sensor 2.
o
Feeder 1 active is associated to feeder 1 relay, feeder 2 active to feeder 2 relay, etc.
•
Defining the Auger Relays
•
Defining the Auger Active Sensors
•
Defining the Feeder Relays
•
Defining the Feeder Active Sensors
7.13.1
D
EFINING THE
A
UGER
R
ELAYS
Define up to two relays as augers (refer to Mapping Devices, page 44).
•
Define:
o
KWh: This field displays the amount of kilowatts used. Read-only.
o
Operation: Define the relay mode.