Manual MVK-MP
56 V 3.5
6.1.2 Mechanical data
6.1.2.1 K3 DO4(DO4)/DIO4(DIO4) Art.-No. 55291
EMC
EN 61131-2
EN 61000-4-2 ESD ............................................ Contact ±4 kV, Air ±8 kV
E EN 61000-4-3 RF-Field + GSM ...................... 10 V/m
EN 61000-4-4 Burst ........................................... ±2 kV
EN 61000-4-5 Surge .......................................... asym./symm. ±500 V (DC power input)
............................................................................ asym. ±1 kV (signal connections)
EN 61000-4-6 HF-asymmetrical ........................ 10 V
EN 61000-4-8 magnet field 50 Hz ...................... 30 A/m
EN 50081-1 interference strength ...................... QP 40 dBµV/m (30 … 230 MHz)
............................................................................ QP 47 dBµV/m (230 … 1000 MHz) Class A
Ambient conditions
Operating temperature ....................................... 0°C ... +55°C
Storage temperature .......................................... -25°C ... +70°C
Protection acc. EN 60529 .................................. IP 67
Materials
Housing ............................................................... zinc die cast, matt nickel coated
Addressing cap ................................................... PA 6-3-T
O-Ring cap .......................................................... Viton, green
O-Ring M12 ......................................................... Viton, green
O-Ring 7/8“ .......................................................... NBR, black
Light comb + ring................................................. PC
Mechanical Environment
Vibration acc. to EN 60068 Part 2-6 .................. 5 … 58 Hz; const. Amplitude 1.5 mm
............................................................................ 58 … 500 Hz; const. acceleration 20 g
............................................................................ Rate of frequency change: 1 Oct/min.
............................................................................ Number of cycles: 10
............................................................................ Function test during testing
Shock acc. to EN 60068 Part 2-27 ..................... Shock shape: Half sinus
............................................................................ Shock acceleration: 50g
............................................................................ Shock duration: 11ms
............................................................................ Directions 6 (positive and negative)
............................................................................ Number of shocks per direction: 3
............................................................................ Function test during testing
Connections
Supply cable ....................................................... 2 x Connector 7/8" female, male
Data cable .......................................................... 2 x M12 connector 5 pole
............................................................................ (female, male, B-coded)
Outputs, inputs, and diagnostic inputs ............... 8 x 5 pole M12 connector (A coded)