EasyManuals Logo

N-Tron 7506GX2 User Manual

N-Tron 7506GX2
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #135 background imageLoading...
Page #135 background image
(Revised 2011-07-21) Page 135 of 158
CLI Commands, Continued…
Show or Set CIP Configuration
Command Name
Cip
Description
Show or set CIP configuration. If no parameters are specified, this command will show
the CIP configuration (same as -show parameter).
Syntax
-Cip [-e[nable] | -d[isable] | -show]
Parameters
-Cip -show
Show CIP configuration.
-Cip [-e[nable] | -d[isable]]
Set the CIP status to e(nabled) or d(isabled).
Examples
N-TRON/Admin> cip -show
CIP Configuration:
------------------
Status: Enabled
EthIp Interval: 10 ms
Cache Interval: 2000 ms
Identity Information:
---------------------
Product Name: N-TRON 7506GX2
Vendor: 1006 (N-TRON)
Device Type: 0x0C (Communications Adapter)
Major Revision: 1
Minor Revision: 1
Serial Number: 0xAFFBA2C0
Connection Information:
-----------------------
Multicast Connections: 0
Unicast Connections: 0
N-TRON/Admin> cip -disable
Changing CIP configuration...
CIP Configuration:
------------------
Status: Disabled
EthIp Interval: 10 ms
Cache Interval: 2000 ms
Identity Information:
---------------------
Product Name: N-TRON 7506GX2
Vendor: 1006 (N-TRON)
Device Type: 0x0C (Communications Adapter)
Major Revision: 1
Minor Revision: 1
Serial Number: 0xAFFBF8F0
Connection Information:
-----------------------
Multicast Connections: 0
Unicast Connections: 0
N-TRON/Admin>