VS1 Operations and Maintenance Manual Operating the transmitter
Page 2-118 Issue 3.1 2013-10-01
Configuring Exgine Settings - VSHD exciter only
The Exgine Settings page allows you to set signal paramaters and determine IP information for use
with the Exgine option (see Figure 2.102 on page 2-119)
Procedure to configure Exgine Settings:
1. Open the User Settings page by pressing Menu/User Settings on the Home page.
2. Select the Exgine Settings option (left-side of the screen) to display a list of pre-existing
notifications on the right-side of the screen. Press Refresh to ensure that the latest Exgine
configuration information is loaded.
3. Enter the following parameters (if applicable) and press Apply.
• Digital Carriers - Select On or Off.
• Protocol - Selects the E2X protocol to use UDP (default) or TCP. Match this setting to
the Exporter configuration.
• Exgine IP, Netmask and Gateway - Configure the Exgine's IP network parameters as
assigned by the local network administrator. If no gateway is used or assigned, enter
0.0.0.0.
• Exporter IP - Enter the Exporter's IP address of the interface where the data stream is
originating. It is used to filter E2X traffic in case multiple exporters are used in broadcast
mode on a single LAN. 0.0.0.0 is also a valid configuration.
• E2X Port - The exgine expects E2X on port 9000. Some non-Nautel Exporters utilize
port 11000 instead.
• Mac Address - Displays a number that serves as unique network adapter identifier. This
is set by the manufacturer and is displayed for informational purposes only. It may be
necessary to use this number to allow the AUI to access your network.