VS1 Operations and Maintenance Manual Operating the transmitter
Page 2-46 Issue 3.1 2013-10-01
Describing the meter display
The meters displayed in the AUI represent the active meters selected for display. Each meter is a
colour-coded bar with minimum and maximum values (see Figure 2.33). The current value for a
meter is indicated by an arrow on the colour-coded bar, as well as a numeric value below the meter.
• A parameter value in the green section of a meter bar indicates the parameter is within
the range for normal operation.
• A parameter value in the yellow section (as applicable) of a meter bar indicates the
parameter is still within an operational range, but is approaching design limitations.
• A parameter value in the red section of a meter bar indicates the parameter is outside
normal operating conditions.
Accessing meter information
Procedures for accessing and editing information in the Meters section of the AUI screen:
• To delete a meter from the Home page, press X in the Meters window (see Figure 2.32
on page 2-45).
• To review all the meter options, press the meter list view shortcut button (magnifying
glass) at the top of the meters panel (see Figure 2.32 on page 2-45). This will open the
Meter List View window.
On the Meter List View screen users can see all relevant meters of a sub-device. Select the sub-
device in question under the Transmitter Layout column and the Relevant Meters column will be
populated. The desired Meters can now be selected.