7167 Owner’s Manual Chapter 6: Commands
November 2003
110
Enable or Disable Panel Buttons
ASCII: ESC c 5 n
Hexadecimal: 1B 63 35 n
Decimal:
27 99 53 n
Value of n :
0 = Enable
1 = Disable
Default:
0 (Enable)
Enables or disables the Paper Feed Button. If the last bit is 0, the Paper Feed Button is
enabled. If the last bit is 1, the Paper Feed Button is disabled so pressing the paper feed
button will result in no response.
Example:
MSComm1.Output = Chr$(&H1B) & Chr$(&H63) & Chr$(&H35) & Chr$(n)
Related Information:
Functions that require using the Paper Feed Button (except for the Execute Macro [1D 5E]
command) cannot be used when it is disabled with this command.