Chapter 6: Commands 7197 Owner’s Guide
February 2002
128
Status Byte (RS-232C)
Bit Function 0 Signifies 1 Signifies
0 Receipt Paper Ok Low
1 Receipt Cover or Front Cover Closed Open
2 Receipt Paper Ok Out
3 Knife Position Ok Jam
4 Not Used Fixed to Zero Fixed to Zero
5 Temperature In valid range Too hot or too cold
6 Voltage In valid range Too high or too
low
7 Not Used Fixed to Zero Fixed to Zero
Example:
• MSComm1.Output = Chr$(&H1B) & Chr$(&H76)
Related Information:
See Real Time Commands, in this document for details about fault condition reporting.