CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 99 – NWA-008847-001 Rev.3.0
a6ch1001.fm
DESCRIPTION DATA
Specify the RS port to make effective the pari-
ty check.
NOTE: When using MP RS-232C port for
MAT, set the initial data.
(1)
(2)
Y=02
0: RS0 port
1: RS1 port
0 : Effective
1 : Ineffective
Specify the kind of parity for the RS port.
NOTE: When using MP RS-232C port for
MAT, set the initial data.
(1)
(2)
Y=03
0: RS0 port
1: RS1 port
0 : Even parity
1 : Odd parity
Specify the stop bit for the RS port.
NOTE: When using MP RS-232C port for
MAT, set the initial data.
(1)
(2)
Y=04
0: RS0 port
1: RS1 port
0 : 1-Stop bit
1 : 2-Stop bit
Specify the DTR signal sent to terminal for the
RS port.
NOTE: When using MP RS-232C port for
MAT, set the initial data.
(1)
(2)
Y=05
0: RS0 port
1: RS1 port
0: Low
1: High
Specify the RTS signal sent to terminal for the
RS port.
NOTE: When using MP RS-232C port for
MAT, set the initial data.
(1)
(2)
Y=06
0: RS0 port
1: RS1 port
0: Low
1: High
Specify the data speed of the RS port.
NOTE: When you communicate with the
modem of PN-CP24-B/PN-CP24-C/
PN-CP24-D/PN-CP27-A/PN-
CP27-B, be sure to set the data
speed of RS1 port as 4800 bps or
more (1200 bps and 2400 bps are
not available).
(1)
(2)
Y=08
0: RS0 port
1: RS1 port
1 : 1200 bps
2 : 2400 bps
3 : 4800 bps
4 : 9600 bps
5 : 19200 bps
NONE : 9600 bps
B
CM40
END
JULY/01/2006
VoIP LOG COLLECTION