6.3 Options
6.3.1 Setup baud rate
Select the serial communication baud rate.
Possible selections are:
1200
2400
9600 (default OSDP)
19200
38400
57600
115200 (default STANDARD)
Click OK after changing the baud rate. Upon success the software will show a message and the baud rate in the
software and reader have been changed. The new baud rate setting in the reader is saved to non-volatile memory.
Note that when using a separate interface converter, it may be required to update the baud rate setting in there as well.
6.3.2 Setup OSDP device address
Select the OSDP device address in range from 0 to 126.
Default device address is 0.
6.3.3 Reset to factory defaults
Reset configuration to factory defaults.
All settings will be reset to factory defaults. The reader will restart automatically afterwards.
This will not affect the TCP/IP network settings.