6.4.4 LED control
Automatic mode
Default the uPASS reader controls the LED automatically.
With “Color UL” the tag read color can be configured. With “Color NA” the color, that indicates that the reader is
waiting, can be configured. These settings will also be used in TRANSIT compatible mode.
Figure 28: LED automatic
Remote control
The LED can be controlled remotely by a connected access control system.
The UL and NA digital inputs determine the color of the LED.
See chapter 3.3.1 for details about the input connections.
Figure 29: LED remote control
Direct control
With direct control, the color can be controlled through serial connection. The color and brightness are directly set via
the serial command (see firmware guide).
Figure 30: LED direct control
OSDP firmware
Use the OSDP_LED command to control the LED.
Automatic mode and Remote control are not supported.