7. PRESET
In programming, certain attribute value (such as colour --- Red/Yellow/Blue…) which is frequently
used can be recorded as PRESET for fast calling.
7.1 Import PRESET
Path: SETUP Fixture
In Fixture menu, press R-Preset soft key, the console will import 20 presets from the library.
(Notice: the custom presets in the console would be covered.)
20 presets will be assigned to 20 preset Numeric Keys as follow:
1 ~ 10:Colour Presets;
11~20:Gobo Presets.
Remark: The above presets need the support of libraries with preset information, if not, presets can’t
be imported but can be edited and recorded manually in the console.
7.2 Call PRESET
1) Select fixtures;
2) Press PRESET key to enter preset status (indicator above will be bright) Press Numeric
Key to select presets
7.3 Customize PRESET
Preset can be customized.
7.3.1 Record PRESET
Remark: Press CLEAR key before editing presets to avoid any unexpected affect;
1) Manual-Run fixtures to edit and modified their attribute to the required effect;
2) Press and hold RECORD (select single or multiple attribute by Attribute Key Select fixtures
by Fixture Numeric Keys) Press Preset Numeric Key to finish
recording;
*TIPS1: the steps in the parentheses() can be skipped. If skip, the console will record all
attribute and fixtures that manually modified.
*TIP2: PRESET only saves the modified attribute. It’s suggested to edit them in “FIND” status.
7.3.2 Delete PRESET
Press and hold DELETE Press Preset Numeric Key to finish deleting
7.3.3 Copy PRESET
For example: copy PRESET 1 to PRESET 5.
Press and hold COPY Press Preset Numeric Key 1 (source)
Press Preset Numeric Key 5 (target) to finish copying