See the VMware documentation for the migration steps.
2. Select the failed node, and select Monitor > Hardware Status > Sensors.
3. Make a note of the serial number of the failed node. The following screenshot is only an example:
You need the serial number to identify the chassis by matching the number that you noted with the serial
number on the sticker at the back of the node.
4. Right-click the failed node and select Connection > Disconnect.
5. Select Yes to confirm the action.
6. Right-click the failed node and select Remove from Inventory.
7. Click Yes to confirm the action.
Replace the node
After you remove the failed node from the cluster, you can remove the failed chassis, and install the
replacement chassis.
Ensure that you have antistatic protection before you perform the steps here.
Steps
1.
Unpack the new chassis, and set it on a level surface.
Keep the packaging material for when you return the failed chassis to NetApp.
2.
Label each cable that is inserted at the back of the chassis that you are going to remove.
After you install the new chassis, you must insert the cables back into the original ports.
3. Disconnect all the cables from the back of the chassis.
4.
Remove the chassis by unscrewing the thumbscrews on the mounting ears.
You must package and return the failed chassis to NetApp.
5. Slide the replacement chassis on to the rails.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp HCI and is the answer not in the manual?

NetApp HCI Specifications

General IconGeneral
Product TypeHyperconverged Infrastructure (HCI)
Data ServicesData protection, encryption
Connectivity10 GbE, 25 GbE, 40 GbE, 100 GbE
Hypervisor SupportVMware vSphere
Management NodeIncluded in the solution
Storage MediaSSD and HDD
Node TypesCompute nodes, storage nodes
Storage ProtocolsiSCSI
Data ReductionDeduplication, compression, thin provisioning
High AvailabilityBuilt-in redundancy

Related product manuals