Talker Declaration Type Identifies the MSRP declaration type of the talker attribute.
Accumulated Latency Identifies how much latency, in nanoseconds, the stream has suffered
in its path from the Talker to a given Listener. It starts as a 0 in a Talker
Advertise Declaration at the Talker, and its value is increased by one
for each bridge as the Talker Advertise Declaration propagates through
the network.
Failure Bridge Interface Identifies the interface on the Bridge where the failure occurred.
Failure Code Shows the number that represents the reason for the failure. The
switch supports the following codes:
1—Insufficient bandwidth
3—Insufficient bandwidth for the traffic class
5—Stream destination_address is already in use
7—Reported latency has changed
8—Egress port is not Audio/Video Bridging (AVB) capable
9—Use a different destination_address (i.e. MAC DA hash table
full)
12—Cannot store destination_address (i.e., Bridge is out of MAC
DA resources)
13—Requested priority is not an SR Class priority
14—MaxFrameSize is too large for media
15—msrpMaxFanInPorts limit has been reached
16—Changes in FirstValue for a registered StreamID
17—VLAN is blocked on this egress port (Registration Forbidden)
Failure Bridge MAC Identifies the MAC address of the switch where the failure occurred.
Stream Age The time, in seconds, since the stream destination address was added
to the Dynamic Reservations Entries table. A value of zero indicates
the destination address has not been added to the table.
Field Description

Table of Contents

Other manuals for NETGEAR GS716T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR GS716T and is the answer not in the manual?

NETGEAR GS716T Specifications

General IconGeneral
Switch typeManaged
Switch layerL3
Quality of Service (QoS) supportYes
Stackable-
CertificationCE, FCC, VCCI, EN, C-Tick, CCC, CSA, UL/cUL, IEC
Product colorBlue
LED indicatorsActivity, Link, Power
SFP module slots quantity2
Basic switching RJ-45 Ethernet ports typeGigabit Ethernet (10/100/1000)
Basic switching RJ-45 Ethernet ports quantity16
Number of VLANs256
Networking standardsIEEE 802.1D, IEEE 802.1as, IEEE 802.1s, IEEE 802.1v, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3i, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z
Copper ethernet cabling technology10BASE-T, 100BASE-TX, 100BASE-T, 1000BASE-T
Noise level0 dB
Mean time between failures (MTBF)567680 h
DHCP featuresDHCP client
Security algorithms802.1x RADIUS, HTTPS, SSL/TLS
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Power consumption (typical)14.4 W
MAC address table16000 entries
Number of static routes32
Operating altitude0 - 3000 m
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Storage relative humidity (H-H)0 - 95 %
Operating relative humidity (H-H)0 - 90 %
Cables includedAC
Supported network protocolsIP
Weight and Dimensions IconWeight and Dimensions
Depth204 mm
Width440 mm
Height43 mm
Weight2570 g