EasyManuals Logo
Home>NETGEAR>Switch>GS716T

NETGEAR GS716T User Manual

NETGEAR GS716T
303 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
46
GS716T and GS724T Gigabit Smart Switches
Denial of Service Min TCP Hdr Size: Specifies the Min TCP Hdr Size allowed. If
First TCP Fragment DoS prevention is enabled, then the switch will drop packets that
have a TCP header smaller than this configured Min TCP Hdr Size. The factory
default is 20.
Denial of Service TCP Fragment: TCP Header size is smaller than the configured
value. Enable or disable this option by selecting the corresponding line on the radio
button. Enabling TCP Fragment DoS prevention causes the switch to drop packets
that have a TCP header smaller than the configured Min TCP Hdr Size. The factory
default is disabled.
Denial of Service TCP Flag: Enable or disable this option by selecting the
corresponding line on the radio button. Enabling TCP Flag DoS prevention causes
the switch to drop packets that have TCP flag SYN set and TCP source port less than
1024 or TCP control flags set to 0 and TCP sequence number set to 0 or TCP flags
FIN, URG, and PSH set and TCP sequence number set to 0 or both TCP flags SYN
and FIN set. The factory default is disabled.
Denial of Service L4 Port: Enable or disable this option by selecting the
corresponding line on the radio button. Enabling L4 Port DoS prevention causes the
switch to drop packets that have TCP/UDP source port equal to TCP/UDP destination
port. The factory default is disabled.
Denial of Service ICMP: Enable or disable this option by selecting the corresponding
line on the radio button. Enabling ICMP DoS prevention causes the switch to drop
ICMP packets that have a type set to ECHO_REQ (ping) and a size greater than the
configured ICMP Pkt Size. The factory default is disabled.
Denial of Service Mx ICMP Pkt Size: If ICMP DoS prevention is enabled and if the
ICMP echo request is carried in an unfragmented IPv4/IPv6 datagram and if the total
length (in the IP header) indicates a value greater than MAX ICMP Size configured +
IP header length, then the specified packet is dropped. The factory default is 512.
2. If you change any of the DoS settings, click Apply to apply the changes to the switch.
3. Click Cancel to cancel the configuration on the screen and reset the data on the screen to
the latest value of the switch.

Table of Contents

Other manuals for NETGEAR GS716T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR GS716T and is the answer not in the manual?

NETGEAR GS716T Specifications

General IconGeneral
Switch typeManaged
Switch layerL3
Quality of Service (QoS) supportYes
Stackable-
CertificationCE, FCC, VCCI, EN, C-Tick, CCC, CSA, UL/cUL, IEC
Product colorBlue
LED indicatorsActivity, Link, Power
SFP module slots quantity2
Basic switching RJ-45 Ethernet ports typeGigabit Ethernet (10/100/1000)
Basic switching RJ-45 Ethernet ports quantity16
Number of VLANs256
Networking standardsIEEE 802.1D, IEEE 802.1as, IEEE 802.1s, IEEE 802.1v, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3i, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z
Copper ethernet cabling technology10BASE-T, 100BASE-TX, 100BASE-T, 1000BASE-T
Noise level0 dB
Mean time between failures (MTBF)567680 h
DHCP featuresDHCP client
Security algorithms802.1x RADIUS, HTTPS, SSL/TLS
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Power consumption (typical)14.4 W
MAC address table16000 entries
Number of static routes32
Operating altitude0 - 3000 m
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Storage relative humidity (H-H)0 - 95 %
Operating relative humidity (H-H)0 - 90 %
Cables includedAC
Supported network protocolsIP
Weight and Dimensions IconWeight and Dimensions
Depth204 mm
Width440 mm
Height43 mm
Weight2570 g