EasyManua.ls Logo

NETGEAR ProSafe GSM7224

NETGEAR ProSafe GSM7224
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software
Switching Commands 8-9
202-10009-01_060204
Underrun Errors - The total number of frames discarded
because the transmit FIFO buffer became empty during frame
transmission.
Transmit Discards
Total Discards - The sum of single collision frames discarded,
multiple collision frames discarded, and excessive frames dis-
carded.
Single Collision Frames - A count of the number of successfully
transmitted frames on a particular interface for which transmis-
sion is inhibited by exactly one collision.
Multiple Collision Frames - A count of the number of success-
fully transmitted frames on a particular interface for which trans-
mission is inhibited by more than one collision.
Excessive Collisions - A count of frames for which transmission
on a particular interface fails due to excessive collisions.
Port Membership - The number of frames discarded on egress
for this port due to egress filtering being enabled.
VLAN Viable Discards - The number of frames discarded on
this port when a lookup on a particular VLAN occurs while that
entry in the VLAN table is being modified, or if the VLAN has
not been configured.
Protocol Statistics
BPDU's received - The count of BPDU's (Bridge Protocol Data
Units) received in the spanning tree layer.
BPDU's Transmitted - The count of BPDU's (Bridge Protocol
Data Units) transmitted from the spanning tree layer.
802.3x Pause Frames Received - A count of MAC Control
frames received on this interface with an opcode indicating the
PAUSE operation. This counter does not increment when the
interface is operating in half-duplex mode.
GVRP PDU's Received - The count of GVRP PDU's received in
the GARP layer.
GVRP PDU's Transmitted - The count of GVRP PDU's trans-
mitted from the GARP layer.
GVRP Failed Registrations - The number of times attempted
GVRP registrations could not be completed.
GMRP PDU's received - The count of GMRP PDU's received in
the GARP layer.

Table of Contents

Other manuals for NETGEAR ProSafe GSM7224

Related product manuals