The heating control system on the FIGHTER 1140 is
controlled by the outside temperature. This means the
flow temperature is regulated in relation to the current
outdoor temperature.
The relationship between the outside temperature and
the flow temperature is set using the control system,
also see section “Heating control system - Basic set-
ting”.
The diagram is based on the dimensioned outdoor
temperature in the area and the dimensioned supply
temperature of the heating system. When these two
values “meet”, the heating control's curve slope can
be read. This is set on menu 2.1 “Curve coefficient”.
Heating curve offset 0
Heating curve offset -2Setting using diagrams
Heating curve offset +2
Heating
curve offset
Menu 2.1 Curve coefficient
9
Curve coefficient
2.1
The “Heating curve offset” knob is then set. A suitable
value for floor heating is -1 and for radiator systems
-2.