VBA10201-R.3577.A
- A46
-
 • Open aperture sensitivity compensation
(1) Set the luminance of the brightness box (shutter tester) to “LV9”.
(2) Set a lens of 50mmF1.4D (a ready-made product) onto the camera.
(3) Set the focus ring of the lens to “innity”.
(4) Select “Open aperture sensitivity compensation” in “Contents” on the menu display.
(5) Supply the power to the camera through the AC cable.
(6) Connect the USB cable to the camera.
(7) Set the camera onto the luminance surface of the brightness box with nearest distance.
(8) Press the START button. Perform the procedure according to the instructions on the screen.
(9) The adjustment result is displayed at the result display position. If “OK” is displayed, the adjustment is
normally ended. If the adjustment is NG,NG” is displayed and the contents of the error are displayed in
the column of “COMMENT”.
(10) Remove the USB cable from the camera and then remove the AC cable.
• Built-in speed light adjustment
(1) Set a lens of 50mmF1.4D (a ready-made product) onto the camera.
(2) Set the focus ring of the lens to “1.4m”.
(3) Set the camera at a 1.4m position from the standard reect paper. Look into the nder to make sure that the
standard reect paper is seen on the whole screen.
(4) Supply the power to the camera through the AC cable.
(5) Connect the USB cable to the camera.
(6) Select “Built-in speed light adjustment” in “Contents” on the menu display.
(7) Press the START button. Perform the adjustment according to the instructions on the screen.
(8) The adjustment result is displayed at the result display position. If “OK” is displayed, the adjustment is
normally ended. If the adjustment is NG,NG” is displayed and the contents of the error are displayed in
the column of “COMMENT”.
(9) Remove the USB cable from the camera and then remove the AC cable.
• Battery check level adjustment
(1) As shown below (Fig. 2), connect the constant-voltage power supply, voltmeter and ammeter to the battery
tool (without resistor).
(2) Set the voltage of the constant-voltage power supply to 7.2 [V].
(3) Set the battery tool (without resistor) onto the camera and start the camera.
(4) Connect the USB cable.
(5) Select “Battery check level adjustment” in “Contents” on the menu display.
(6) Press the START button. Perform the procedure according to the instructions on the screen.
(7) The adjustment result is displayed at the result display position. If “OK” is displayed, the adjustment is
normally ended. If the adjustment is NG,NG” is displayed and the contents of the error are displayed in
the column of “COMMENT”.
(8) Remove the USB cable from the camera and then remove the AC cable.