EasyManua.ls Logo

Nokia 7368 ISAM ONT G-240W-C - Maintenance; Table 57 Device Information Parameters

Nokia 7368 ISAM ONT G-240W-C
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ONT configuration file over OMCI
158
7368 ISAM ONT G-240W-C Product Guide
3FE-46256-AAAA-TCZZA Issue: 01
Procedure 62 Configuring an ONT using a configuration file via OMCI
1 Generate the TAR file to be uploaded to the OLT.
Using the raw configuration file(s) provided by Nokia, generate the TAR file as follows:
i On a Linux platform, rename the raw configuration file to adhere to the naming
convention, as described in section 8.2.
ii Tar the ABCXXXXVER raw configuration file:
tar -cf ABCXXXXVER.tar ABCXXXXVER
Where
ABCXXXXVER
Is the name of the file created in step i.
This creates two files: ABCXXXXVER and ABCXXXXVER.tar.
iii Rename ABCXXXXVER to ABCXXXXVER.org
iv Remove the “.tar” extension from ABCXXXXVER.tar file.
2 Upload the ABCXXXXVER TAR file to the /ONT/ directory in the OLT.
A maximum of 250 files can be kept in the OLT file system.
3 Using OLT commands, download the TAR file to the ONT.
For OLT commands, refer to the 7360 ISAM FX CLI Command Guide for 100_320Gbps FD
NT and FX NT, or the 7342 ISAM FTTU Operation and Maintenance Using TL1 and CLI.
Please note:
pri-cfgfile-pland/dnload or sec-cfgfile-pland/dnload can be 1 to 14
characters.
pri-cfgfile-pland and pri-cfgfile-dnload should be the same name.
Examples
Note: X can be 1 or 2 unless specified:
i If pland-cfgfileX= Disabled and dnload-cfgfileX= Disabled ,
no file will be downloaded to the ONT.
ii If pland-cfgfileX=FILENAME1 and dnload-cfgfileX= Disabled ,
FILENAME1 will be downloaded and FILENAME1 will be made active. An ONT reboot
is required.
iii If pland-cfgfileX=Disabled and dnload-cfgfileX= FILENAME2
Release 06.01.00 | March 2019 | Edition 12

Table of Contents

Related product manuals