G-240W-C unit data sheet
40
7368 ISAM ONT G-240W-C Product Guide
3FE-46256-AAAA-TCZZA Issue: 01
To keep the Nokia solution independent from the carrier’s ACS, the ONT can
establish an independent TR-069 session with the Saas.
The Saas WiFi Care URL and credentials can be programmed from the carrier’s ACS
solution, or they can be incorporated in a pre-configuration file.
4.2.5 TR69 authentication using TLS and CA certificates
G-240W-C ONTs support TLS, as well as ACS authentication using SHA-256
pre-installed certificates.
If the URL is set to the https://... format, by default, the connection will use TLS
without authentication mode. The ONT can also authenticate the ACS using a
pre-installed CA certificate.
4.2.6 TR-104 parameter extension support for voice
service
A proprietary attribute has been added to the TR-104 Voice Service object structure
to enable the ACS to configure the name of the embedded GSIP XML file to be
selected.
The TR-104 Voice Service Object is:
InternetGatewayDevice.Services.VoiceService.{i}.Capabilities.SIP.
The proprietary attribute is: X_ALU-COM_XML_File_Name_Path.
4.2.7 TR-104 voice-related alarms
The G-240W-C ONT supports the following four TR-104 voice-related alarms on a
per FXS port basis.
These alarms all represent SIP registration failures with an alarm level of MAJOR.
SIPREGDNS: domain name could not be resolved
SIPREGAUTH: authentication failed
SIPREGTO: re-transmissions timed out
SIPREGERR: error response from the registration server