G-240W-C unit data sheet
50
7368 ISAM ONT G-240W-C Product Guide
3FE-46256-AAAA-TCZZA Issue: 01
 
Table 9 G-240W-C indoor ONT power consumption specifications
Table 10 lists the environmental specifications for G-240W-C indoor ONT.
Table 10 G-240W-C indoor ONT environmental specifications
4.7 G-240W-C GEM ports and T-CONTs
Table 11 lists the maximum number of supported T-CONTs and GEM ports. See the 
appropriate release Customer Release Notes for the most accurate list of supported 
devices.
Table 11 G-240W-C indoor ONT capacity for GEM ports and T-CONTs
Mnemonic Maximum 
power (Not to 
exceed)
Condition Minimum 
power
Condition
G-240W-C 30 W 2 POTS off-hook, 4 
10/100/1000 Base-T 
Ethernet, Wi-Fi operational
12 W 2 POTS on-hook, other 
interfaces/services not 
provisioned
Mounting 
method
Temperature range and humidity Altitude
On desk or wall 
mounted
Operating: 23°F to 113°F (-5°C to 45°C) 
ambient temperature
10% to 90% relative humidity, 
non-condensing
Contact your Nokia technical support 
representative for more information
Storage: -4°F to 158°F (-20°C to 70C)
ONT or MDU Maximum Notes
Package P ONTs
GEM ports per indoor or outdoor ONT 124  124 are present; 122 are available, and 2 are 
reserved for multicast and debugging
T-CONTs per indoor or outdoor ONT 32 32 are present; 31 are available, and 1 is 
reserved for OMCI
Release 06.01.00 | March 2019 | Edition 12