Battery endurance
Battery Capacity (mAh) Talk time Stand-by
BP-5L 1500 up to 6 hrs up to 12 days
Charging times
ACP-4
2 h 10 min
Environmental conditions
Environmental condition Ambient temperature Notes
Normal operation
-15
o
C...+55
o
C
Specifications fulfilled
Reduced performance
-25
o
C...-15
o
C
+55
o
C...+70
o
C
Operational for shorts periods
only
Intermittent operation
-40
o
C...-15
o
C
+70
o
C...+85
o
C
Operation not guaranteed but an
attempt to operate does not
damage the phone.
No operation or storage
<-40
o
C...>+85
o
C
No storage or operation: an
attempt may damage the phone.
Charging allowed
-25
o
C...+50
o
C
Long term storage conditions
0
o
C...+85
o
C
DC characteristics
Signal Min Nom Max Note
VBAT 3.1V 3.7V 4.2V (charging
high limit voltage
3.1V SW cut off