FS-5 Product specific
adapter
RM-88/RM-89 specific adapter.
MJ-67 Module jig
RM-88/RM-89 specific module jig.
•
Table 7 Attenuation table for MJ-67
System Channel Tx/Rx-att. (dB)
GSM 850 128 0.2
190 0.1
251 0.1
GSM 900 975 0.1
38 0.1
124 0.2
GSM 1800 512 0.3
698 0.2
885 0.1
GSM 1900 512 0.5
700 0.6
810 0.8
Measured with Universal Radio Communication Tester CMU-200.
Note: Tx-attenuation tolerance is +/- 0.5dB
Rx-attenuation tolerance is +/- 1.0 dB
RJ-86 Soldering jig
RM-88/RM-89 specific soldering jig.
RM-88
Nokia Customer Care Service Tools and Service Concepts
Page 4 –8 COMPANY CONFIDENTIAL Issue 1
Copyright © 2006 Nokia. All rights reserved.