5 Parameter
BU 0240 en-US-4920 65
5 Parameter
Pos: 27 2 /Anlei tung en/El ektr onik/FU und Star ter/1 . Allg emei nes/Sic herh eits- und Ins tall ations hinwei se un d Warn- Gefahrenhinweise/neu/Warn- un d Gefa hrenhi nweis e/WAR NUN G - Unerw arte te B ew egu ng [U mr icht er] @ 3 3\mod_1557225504645_14638.docx @ 2533756 @ @ 1
WARNING
Unexpected movement
Connection of the supply voltage may directly or indirectly set the device into motion. This may cause
unexpected movement of the drive and the attached machine, which may result in serious or fatal
injuries and/or material damage. Possible causes of unexpected movements are e.g.:
Parameterization of an "automatic start"
Incorrect parameterization
Control of the device with an enabling signal from a higher level control unit (via I/O or bus
signals)
Incorrect motor data
Incorrect encoder connection
Release of a mechanical holding brake
External influences such as gravity or other kinetic energy which acts on the drive unit
In IT systems: System fault (ground fault)
To avoid any resulting hazard, the drive or drive chain must be
secured against unexpected
movements (mechanical blocking and/or decoupling, provision of protection against falling, etc.). In
addition, make sure that there are no persons within the area of action and the danger area of the
system.
Pos: 27 3 /Anlei tung en/El ektr onik/FU und Star ter/1 . Allg emei nes/Sic herh eits- und Ins tall ations hinwei se un d Warn- Gefahrenhinweise/neu/Warn- un d Gefa hrenhi nweis e/WAR NUN G - Unerw arte te B ew egu ng d urch V eränd er n der Par am etr ieru ng [ SK x xx E] @ 49 \mod_1599037700449_14638.docx @ 2665881 @ @ 1
WARNING
Unexpected movement due to parameter changes
Parameter changes become effective immediately. Dangerous situations can occur under certain
conditions, even when the drive is stationary. Functions such as P428 "Automatic starting" or P420
"Digital inputs" or the "Brake off" setting can put the drive in motion and put persons at risk due to
moving parts.
Therefore:
Changes to parameter settings must only be made when the FEHLER - Variable ohne Inhalt is not
enabled.
During parameterization work precautions must be taken to prevent unwanted drive movements
(e.g. lifting gear plunging down). The danger area of the system must not be entered.
Pos: 27 4 /Anlei tung en/El ektr onik/FU und Star ter/1 . Allg emei nes/Sic herh eits- und Ins tall ations hinwei se un d Warn- Gefahrenhinweise/neu/Warn- un d Gefa hrenhi nweis e/WAR NUN G - Unerw arte te B ew egu ng d urch Üb erl ast @ 3 2\mod_1553502436617_14638.docx @ 2519396 @ @ 1

Table of Contents

Other manuals for Nord Drivesystems NORDAC FLEX SK 215E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nord Drivesystems NORDAC FLEX SK 215E Series and is the answer not in the manual?

Nord Drivesystems NORDAC FLEX SK 215E Series Specifications

General IconGeneral
BrandNord Drivesystems
ModelNORDAC FLEX SK 215E Series
CategoryInverter
LanguageEnglish

Related product manuals