Installation
3-8
Part 1618871−01
2020 Nordson Corporation
Terminations
Terminations are determined by the system configuration. Figure 3-4 shows
terminations for a system with an auxiliary cabinet and 4 manual spray
guns. Refer to Table 3-3 for terminations on other types of system
configurations.
NOTE: If there are no connections to P4 or P5, the termination jumper
must be installed on JP1 on the flow module in the main controller.
Table 3-3 CAN Termination Locations
System Configuration CAN Termination Locations
32 Automatic Spray Guns
(includes main and auxiliary cabinets)
PLC
CAN A on Auxiliary Backplane
(SW1-3 − see Figure 3-6)
16 Automatic Spray Guns
(main cabinet only)
PLC
Flow Module 1 (see JP1 − See Figure 3-5)
12 Automatic Spray Guns and 4 Manual Spray
Guns (includes main only)
PLC
After MGI 4
10017279/10018617
JP1
Figure 3-5 iFlow Board