Scanning 29
Scanning in Hollerith Check mode
The Océ 3050 Microfilm Scanner feeds a card, scans the card and displays the
Hollerith data in the Run-Time Display window. Errors in the Hollerith coding
can be corrected with edit in the Run-Time Display window.
Note: This mode is not useful when the aperture cards are not punched.
Settings in the Control window
Before starting the scanner, you set the scanning controls in the Control
window.
To start a scanning session in Hollerith Check mode:
1 Click the Hollerith Check button in the Running Mode entry box.
2 Select the Hollerith in the Input Size entry box.
3 Select the required Output Mode.
4 If the output mode is set to Print or Print/File, set the Print Control settings as
required.
5 Place the aperture cards in the input hopper.
6 Click the Start button to start the scanning session.
7 If required, set the names for image files and log file (see figures 9 and 10 on
page 22).
The system switches to the Run-Time Display window (see figure 12 on
page 30).