ENTERING SETTINGS -SET MODE #1
TO SET - FO2 (while in the Surface Mode)
Factory set for AIR, FO2 can also be set to values between
21 and 50% in increments of 1%.
• Press Both buttons simultaneously, release when SET: 1
appears (2 seconds).
• Press and release the Left (Advance) button, FO2 ap-
pears with the set point value flashing (Fig. 19).
• Press and release the Right (Select) button repeatedly to
increase the FO2 value from 21 to 50% in increments of
1%, then display AIR again; - or - Press and hold the
Right (Select) button to scroll from AIR to 32%, then press
and hold again to scroll from 32 to 50%, then AIR.
• For each FO2 value that appears, the display indicates
the Maximum Depth that can be achieved for a PO2 of
1.60 ATA (Fig. 20a), or the PO2 Alarm set point. If FO2
is set for AIR, no Depth value is displayed.
• Press the Left (Advance) button to accept the setting and
advance to Set Depth Alarm, or press and hold Both
buttons for 2 seconds to revert to Surface Mode.
Fig. 19 - Set FO2
Fig. 20 - FO2 set for 32%
a
ATR
O
2
N
2