ATR
O
2
N
2
TO SET - BACKLIGHT DURATION
(while in the Surface Mode)
Factory set for 3 seconds, the Backlight Duration can be set
to values of 0 (disabled), 3, or 7 seconds. This is the length
of time the Backlight stays On after the button is released.
• Press Both buttons simultaneously, release when SET: 2
appears (4 seconds).
• Press and release the Left (Advance) button, the Units
screen appears with the set point flashing.
• Press the Left (Advance) button 15 more times.
• The graphic GLO and Time icon appear with the Dura-
tion value flashing (Fig. 39).
• Press and release the Right (Select) button to advance the
Duration from :00 to :03 to :07 (seconds).
• Press the Left (Advance) button to accept the setting and
advance to Set Sampling Rate, or press and hold Both
buttons for 2 seconds to revert to Surface Mode.
Fig. 39 - Set Backlight Duration