34
DECO
ATR
O
2
N
2
TO SET - MAXIMUM TISSUE LOADING BAR GRAPH
(TLBG) ALARM (while in the Surface Mode)
Factory set for DECO (all 8 segments), the Maximum Tissue
Loading Bar Graph (TLBG) Alarm can be set to values
between DECO (all 12 segments) and 1 segment.
• Press Both buttons simultaneously, release when SET: 2
appears (4 seconds).
• Press and release the Left (Advance) button, the Units
screen appears with the set point flashing.
• Press the Left (Advance) button 8 more times.
• The graphic ndc and Alarm (speaker) icon appear with
the full TLBG flashing (Fig. 32).
• Press and release the Right (Select) button to decrease
the number of segments one at a time.
• Press the Left (Advance) button to accept the setting and
advance to Set Air Time Remaining Alarm, or press and
hold Both buttons for 2 seconds to revert to Surface
Mode.
Fig. 32 - Set Max TLBG Alarm