PROPLUS X OPERATING MANUAL
© Pelagic, 2016 Doc. No. 12-5655-r01 (8/19/16)
DELAYED VIOLATION 3
If you descend deeper than the maximum functional depth*, the audible alarm will sound. Also, the up arrows, and TOO DEEP message will ash.
Only dashes will display for Current Depth and NDC (No Decompression) time signifying that you are too deep.
* The maximum functional depth (Dive/Gauge = 330 ft / 100 m) is the depth at which the ProPlus X can properly perform calculations or provide accurate display information.
Upon ascending above the maximum functional depth, current depth will be restored. However, the log for that dive will display dashes for max
depth.
DELAYED VIOLATION 1
If you remain shallower than a Deco Stop Depth for more than 5 minutes, operation will enter Delayed Violation 1* which is a continuation of
Conditional Violation with penalty time still being added. Again, the audible alarm will sound and the full Tissue Loading Bar Graph will ash until it
is silenced.
*The difference is that 5 minutes after surfacing from the dive, operation will now enter Violation Gauge Mode.
Down arrow and DOWN TO STOP message continues to ash until descending below the required Stop Depth.
If the Delayed Violation 1 status is ignored, the ProPlus X will enter Delayed Violation 1 Surface mode for 5 minutes upon surfacing from the dive.
Down arrows and Deco Stop depth/time will alternate with VIOLATION. After 5 minutes on the surface in DV1 mode, the unit will enter VGM
(Violation Gauge Mode).
AR
%
11
GAS 1
-AIR
FO2
PO2
-
20
14
FT
100
TL
%
1198
PSI
(v) TO MENU - (>) TO COMPASS
15
15
DECO STOP
GTR
FT
DOWN TO
STOP
DV 1 Dive Main
GAS 1
-AIR
FO2
PO2
-
20
100
TL
%
1198
PSI
(v) TO MENU - (>) TO COMPASS
15
15
DECO STOP
FT
GTR
DOWN TO
STOP
0 01
SURF
:
:
DV 1 < 5 Min On Surface
DELAYED VIOLATION 2
If the calculated Decompression obligation requires a Stop Depth between 60 ft (18 m) and 70 ft (21 m), operation will enter Delayed Violation 2.
The audible alarm will sound. Additionally, the full Tissue Loading Bar Graph will ash until the audible is silenced.
• Up arrows ash if 10 ft (3 m) deeper than the required Stop Depth.
Once within 10 ft (3 m) of and below the required Stop Depth, the DECO STOP message will be displayed.
AR
%
11
SPG
GAS 1
36%
FO2
PO2
1.40
60
72
FT
100
TL
%
(v) TO M ENU - (>) TO COMPASS
2
FT
DECO STOP
DECO
66°F
12:26
PM
70%
AR
%
11
GAS 1
-AIR
FO2
PO2
-
---
FT
54
TL
%
1261
PSI
(v) TO MENU - (>) TO COMPASS
-- 37
EDT
21
GTR
DEE P
TOO
NDC

Table of Contents