29
ODB COMPANY
800-446-9823 LCT6000
Operating Section
3.1 Starting Engine
Always make sure the PTO is disengaged before starting
unit. (See gure 3b)
oroughly read and understand the safety and pre-operat-
ing sections of this manual before staring the engine.
DO NOT start the engine in an enclosed building. Proper
ventilation is required before starting the engine.
Throttle Control
The Module Uses J1939 throttle aka Torque Speed Control (TSC1)
PRIOR TO STARTING ENGINE, select the proper throttle control mode and parameters required for ap-
plication
Throttle is set through the Throttle Conguration Menu in the Control module
*Under CAN Conguration, you will nd Throttle Type Selection / TSC Min Speed / TSC Max Speed /
TSC Ramp Rate / Throttle Curve Selection*
Manual rottle Options
1) Vernier rottle
Standard Up and Down Throttle between the set Minimum and Maximum selections.
The Ramp rate is the rate of acceleration in RPMs per second.
2)Multistate rottle
Provides for one, two, three, or four specic operating speeds. Pressing the Up and
Down Buttons adjusts engine speed between the selected multistate speed selections.
3) High/Low
Engine Accelerates to the Max Speed Setting with the Up button pressed. When the Up
button is released, the engine goes back to idle speed.