ODB COMPANY
800-446-9823 LCT6000
Service Section
Review the safety section of this manual before attempt-
ing these procedures. To gain access to the interior of the
blower housing please see the previous sections.
oroughly read and understand the safety and pre-operat-
ing sections of this manual before working on the unit.
gure 5.5a
Install the long liner the same way as the short
liner except the long liner should slip under the
overlap piece. Make sure the liner slips under the
rear lip and the overlap piece.
Tack weld the long liner to the overlap piece and
tack weld around the liner as you did on the short
liner.
Install the two bolt-in liners just as they were
removed.
Installing the Liners (refer to 5.5a and 5.5b), continued;
3.
4.
5.
Make sure the negative battery cable is disconnected before
opening the blower housing.
gure 3c
Keep all fuel and fuel fumes away from the
unit when grinding or welding. Work only
in a well ventialted area.
Weld
Weld
Stop
Piece
Weld
Lip
Overlap
Piece
gure 5.5b
5.7 Replacing the Blower Housing Liners; continued,