Inverter Power Supply Failure
Error Codes that Apply
097
1. Cycle the printer's power.
2. If the problem persists follow the procedure below.
1. Inverter Power Supply
2. Inverter Interface Cable
3. Inverter Power cord
4. Engine Control Board
Steps Action Taken Yes No
1
Check the following for evidence of
fault or damage:
Inverter Power Cord
Inverter Power Supply
Is there any damage?
Replace any damaged
parts.
Go to Step 2.
2
Check AC Power.
Is the AC voltage available at the
outlet?
Go to Step 3.
Advise customer.
3
Check the Inverter connection.
Is the Inverter interface cable
securely connected at both ends?
Go to Step 4.
Connect the
Inverter to the
Finisher.
4
Replace the Inverter Power Supply.
Does the error persist?
Replace the Inverter
Control Board.
Complete.