%Line Feed Control
Line Feed Control
The line feed command (ASCII LF, decimal 10)
tells the ML380 to print a line and then move the print position
down one line on the page. The amount of vertical movement depends
on the current line spacing (see above). This command also cancels
one-line double width printing.Use the ESC J n command to
execute fine line feeds in increments of 1/180-inch. Unlike the
simple LF code, the ESC J n code doesn't cancel one-line double
width printing. If you substitute 0 for the n, no line feed will be
performed.