45641001TH Rev.1
10-4 /
Oki Data CONFIDENTIAL
5.BKCTRsignal,MNCTRsignal,FLCTRsignal(outputsignals)
These signals become“Low” (ON) synchronizing with the CTRON signal according to the
copying mode used. The pulse width corresponds to the fixed time. Though the CTRON
signalissetto“Doublecount”,theyarenotoutputtedsynchronizingwiththesecondcount
signal.
6.SIZE3,SIZE2,SIZE1andSIZE0signals(outputsignals)
These 4 signals are outputted in the combination of 4 sizes for the paper to be copied.
Theyarethesignalsforthecoincontroller,andareoutputtedfromtheLGCboard.
7.LARGE/SMALLsignal(outputsignal)
Whenlargesizepaper(A3/A3wide/LD)isselectedorpapersizeisnotspeciedwiththe
manual feeding,it outputs“Low” in real time. In other cases, it outputs“High”.The setting
changeforlargesizepaperisperformedwithF/W.
This is the signal only for the coin controller.
8.FULLCOLORsignal(outputsignal)
Ifthefullcolormodeisselected,itoutputs“Low”inrealtime.Inothercases,itoutputs“High”.
Bydefault,itoutputs“Low”sinceitissetasfullcolormode.
This is the signal only for the coin controller.
9.TWN/MONCOLORsignal(outputsignal)
Ifthetwincolorormonocolormodeisselected,itoutputs“Low”inrealtime.Inothercases,
itoutputs“High”.Thisisthesignalonlyforthecoincontroller.
10.B/Wsignal(outputsignal)
Iftheblackmodeisselected,itoutputs“Low”inrealtime.Inothercases,itoutputs“High”.
This is the signal only for the coin controller.
11.KCTRONsignal(outputsignal)
Thesesignalsaresynchronizedwiththeelectroniccounteroftheequipmentandthey
become“Low”whenthecounteristurnedON.Theyarethesignalsfordrivingamechanical
counter,andoutputfromtheLGCboard.
Theycandriveinductiveloads,suchasasolenoid,using24Vsuppliedfromtheequipment.
The interval between when they are turned ON and when this happens next must be at least
100 ms.“Single count”or“Doublecount”can be switchedaccording to the paper sizeby
setting“1”or“2”for08-6010.

Table of Contents

Other manuals for Oki MPS5502

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oki MPS5502 and is the answer not in the manual?

Oki MPS5502 Specifications

General IconGeneral
BrandOki
ModelMPS5502
CategoryAll in One Printer
LanguageEnglish

Related product manuals