EasyManua.ls Logo

Oki MPS5502 - Communication Related Service Call

Oki MPS5502
390 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
45641001TH Rev.1
5-40 /
Oki Data CONFIDENTIAL
5.3.4 Communication related service call
[F070] Communication error between SYS board and PU board
Classification Error content
Communication related
service call
Communication error between SYS board and PU board
Check item Measures
Error code • TurnthepowerOFFandthenbackONusingthemainpowerswitch,
and then check if the error code changes to another one.
• Ifitchangestoanotherone,followtheprocedureforthechangederror
code.
Check firmware version • ChecktheversionofthesystemrmwareontheSYSboard.
• ChecktheversionofthePUrmwareonthePUboard.
Board check • CheckiftheconnectorCN118,CN119ontheSYSboardandthe
connectorCUIF0,CUIF1onthePUboardarecompletelyinserted.
• CheckiftheconnectorpinbetweentheSYSboard(connectorCN118,
CN119)andthePUboard(CUIF0,CUIF1)isdisconnected.
• CheckiftheconnectorsHEAD0K,HEAD1Y,HEAD2M,andHEAD3C
oftheLEDheadarecompletelyinserted,andtheharnessis
disconnected or open circuited.
• CheckiftheconductorpatternsonthePUboardandSYSboardare
short circuited or open circuited
Parts to be replaced Remark
SYS board
PU board
LEDhead
[F071] Communication initialization error between SYS board and PU board
Classification Error content
Communication related
service call
Communication initialization error between SYS board and PU board
Proce-
dure
Check item Measures
1 LEDhead,harness 1-1.DisconnectalltheharnessesoftheLEDheads,andthenturn
the power ON. Check if the error changes to another service call.
(HEAD0K,HEAD1Y,HEAD2M,HEAD3C)
1-2.Iftheerrordoesnotchangetoanotherservicecallinstep1-1,goto
step2.Iftheerrorchangestoanotherservicecall,followthesteps
below.
1-3.ConnecttheharnessesoftheLEDheadtothePUboardsingle
coloratatime,andthenturnthepowerONtoidentifytheLEDhead
in error. Check if F071 occurs. Place the parts causing the error.
Y color: HEAD1Y
M color: HEAD2M
C color: HEAD3C
Kcolor:HEAD0K
2 Check firmware
version
• ChecktheversionofthesystemrmwareontheSYSboard.
• ChecktheversionofthePUrmwareonthePUboard.