45641001TH Rev.1
11-20 /
Oki Data CONFIDENTIAL
05/
08
Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
Mode
System User
interface
Card reading
device
3502
Card reader
format
information
-2
0 0-
42949
67295
SYS
The data of the block number in the noncontact IC
is set.
KP-2003:<PPQRSSTU(hexadecimal
number)>
PP: 1st
block
Q: 1st block beginning
byte
R: 1st block ending
byte
SS:
2nd
block
T: 2nd block beginning
byte
U: 2nd block ending
byte
KP-2005:<RRBSEbse(hexadecimal
number)>
RR: 00
(Fixed)
B: 1st area block
number
S: 1st area beginning byte
offset
E: 1st area ending byte
offset
b: 2nd area block
number
s: 2nd area beginning byte
offset
e: 2nd area ending byte
offset
*Ifthe2ndblock/areaisnotused,settheSSTU
to
“FFFF”
(hexadecimalnumber),thebse
to”FFF”
(hexadecimal
number).
5
08 Setting
Mode
System User
interface
Card reading
device
3503
Card reader
format
information
-3
0
Refer
to
contents
SYS
Securitykey“KKKKKKKKKKKK”(12
digits)
<hexadecimalnumber>inthe[KeyInformation]of
the
[SectorNumber]setinthecode08-3501should
be entered.
<Acceptable
value>
0-0xFFFFFFFFFFFFFFFF
5
08 Setting
Mode
System User
interface
Card reading
device
3504
Card
authentication
LDAP
server
0 0-100 SYS
LDAPservernumberforthecardauthentication
when
a
noncontact IC card is used should be
set.
1
08 Setting
mode
System General
ListprintUSB
storage setting
3615
ListprintUSB
storage setting
0 0-1 SYS
0: Enable (USB storage
available)
1: Disable (USB storage not
available)
1
08 Setting
mode
System General
Real time
log
notification
function
3623
Job filtering
setting 0 0-65535 SYS
Changesthetargettypeofjobsfornoticationin
real
time log notification
function.
1
08 Setting
mode
System General
Real time
log
notification
function
3624
Logitem
filtering
setting
21474
83921
0-
42949
67295
SYS
Changes the target type of logs for notification in
real
time log notification
function.
5
08 Setting
Mode
System General Real time log
notification function
3626 Department
information
transmission
setting
0 0-1 SYS Setswhetherthedepartmentinformation(number,name,
code) is transmitted or not in the real time log notification
function.
0:Departmentnumber,departmentname,department
code
1:Departmentnumber,departmentname
1
08 Setting
mode
System General 3629 Enable/Disable
setting of standard
EWBfunction
1 0-1 SYS 0: Disabled
1: Enabled
1