45641001TH Rev.1
11-33 /
Oki Data CONFIDENTIAL
05/
08
Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
Mode
Counter Custom
counter
Quota control Weighting/
Scanning
6081 0 Black/Gray 100 0-9999 SYS WeightsadditionofScanCountertoCustomCounter.
SincethecountiscalculatedbasedontheexistingLarge/
Smallcounter,thecountbeforechangingthissettingis
also included in the count.
0 (weight: 0.00) – 9999 (weight: 99.99)
4
08 Setting
Mode
Counter Custom
counter
Quota control Weighting/
Scanning
6081 1 Full Color 100 0-9999 SYS WeightsadditionofScanCountertoCustomCounter.
SincethecountiscalculatedbasedontheexistingLarge/
Smallcounter,thecountbeforechangingthissettingis
also included in the count.
0 (weight: 0.00) – 9999 (weight: 99.99)
4
08 Setting
Mode
Counter Double
count
For charging Paper type 6083 1 Thick1/2/3/4/5 0 0-1 SYS Sets the weight of fee charging count for printing per
page.Scancounterandfaxcounterarenotinuenced.
0: Single
1: Double
4
08 Setting
Mode
Counter Double
count
For charging Paper type 6083 2 Special1(Label1)/
Special2(Label2)/
Special3(Transparency) /
Special4(Glossy1) /
Special5(Glossy2) /
Special6(Glossy3)
0 0-1 SYS Sets the weight of fee charging count for printing per
page.Scancounterandfaxcounterarenotinuenced.
0: Single
1: Double
4
08 Setting
Mode
Counter Double
count
For charging Paper type 6083 4 Envelope1/2/3/4 0 0-1 SYS Sets the weight of fee charging count for printing per
page.Scancounterandfaxcounterarenotinuenced.
0: Single
1: Double
4
08 Setting
Mode
Counter Double
count
For charging Paper type 6083 6 UserType1/2/3/4/5 0 0-1 SYS Sets the weight of fee charging count for printing per
page.Scancounterandfaxcounterarenotinuenced.
0: Single
1: Double
4
08 Setting
Mode
Counter Custom
counter
Quota control 6084 Print weight and
Quota type
0 0-1 SYS SetsthetypeofQuota.Whenthevalueofthiscodeis
setto“1”,thevalueof08-9116issetto“0”(Blackfree
function is OFF).
0: Color/Black Quota
1: Job Quota
1
08 Setting
Mode
Counter Custom
counter
Quota control Weighting/Print 6085 0 Black/Small 100 0-9999 SYS WeightsadditionofprinttoCustomCounterandJob
Quota.
0 (weight: 0.00) – 9999 (weight: 99.99)
4
08 Setting
Mode
Counter Custom
counter
Quota control Weighting/Print 6085 1 Black/Large 100 0-9999 SYS WeightsadditionofprinttoCustomCounterandJob
Quota.
0 (weight: 0.00) – 9999 (weight: 99.99)
4
08 Setting
Mode
Counter Custom
counter
Counter Settings 6086 DisplayinWeb
Page
0 0-1 SYS Sets whether the counter settings (screen of weighting
settingofcustomcounter)aredisplayedinWebPagefor
administrator,orsetbycode08-6081and6085only.
0:OFF(NotdisplayedinWebPage)
1:ON(DisplayedinWebPage)
1