Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System Network SSL 9556 SSLPOP3Client
OFF/ON
2 1-3 - OFF/ON
1:Valid(Acceptsallthecerticationoftheserver)
2: Invalid
3: Use the imported certification.
12
08 Setting
mode
System Network TCP/IP 9563 IPConictDetect 1 1-2 - OFF/ON
1:Valid
2: Invalid
12
08 Setting
mode
System Network SNTP 9564 SNTP Enable 2 1-2 - OFF/ON
1:Valid
2: Invalid
12
08 Setting
mode
System Network DHCP 9580 Enabling server’s
IP address
acquiredbyDHCP
1 1-2 - Domain Name Server option (6)
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
12
08 Setting
mode
System Network DHCP 9581 Enabling server’s
IP address
acquiredbyDHCP
1 1-2 - NetBIOSoverTCP/IPNameServeroption(44)=Primary
andSecondaryWinsNAME
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
12
08 Setting
mode
System Network SMTP 9584
SMTP Server
Option (69) Simple
Mail Server Address
2 1-2 - OFF/ON
1:Valid
2: Invalid
12
08 Setting
mode
System Network POP3 9585 POP3 Server
Option (70) Post
Office Server
Address
2 1-2 - OFF/ON
1:Valid
2: Invalid
12
08 Setting
mode
System Network DHCP 9587 Enabling server’s
IP address
acquiredbyDHCP
2 1-2 - SNTP Server Option (42) NTP Server Address
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
12
08 Setting
mode
System Network SMB 9599 Samba server
ON/OFF setting
1 1-4 NIC 1: Samba enabled
2: Samba disabled
3: Print Share disabled
4: File Share disabled
12
08 Setting
Mode
System
Maintenance
General 9601 Equipmentnumber
(serial number)
display
- 9 digits SYS Fist digit: Production country (fixed)
Second digit: Model (fixed)
Third digit: Month (variable)
Fourth to ninth digit: serial number (variable)
This can be also entered with 05-9043.
11
08 Setting
mode
System
Maintenance
9602 Dealer'sname - - SYS Maximum 100 letters Needed at initial registration 11
08 Setting
Mode
System
Maintenance
RDMS 9603 Loginname - 20 letters SYS Maximum 20 letters
Needed at initial registration
11