45641001TH Rev.1
11-81/
Oki Data CONFIDENTIAL
05/
08
Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System
Maintenance
RDMS Longinterval
polling
9626 Setting of polling at
the end of month
0 0-1 SYS 0: Invalid
1:Valid
1
08 Setting
mode
System Network InternetFAX 9627 Sending mail text
ofInternetFAX
1 0-1 SYS 0: Invalid
1:Valid
1
08 Setting
mode
System Network SMTP 9628 From Name
Creation setting
in SMTP
authentication
0 0-2 SYS 0: Not edited
1: Account name of From Address +Device name
2:LDAPsearching
1
08 Setting
mode
System Wireless
LAN
9649 WirelessLAN
setting
2 1-2 NIC SetswhetherthewirelessLANconnectionisenabledor
disabled.
1: Enabled
2: Disabled
12
08 Setting
mode
System Network DHCP 9694 Enabling server’s
IP address
acquiredbyDHCP
1 1-2 - DNS domain name Option (15) DNS domain name of the
client
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
12
08 Setting
Mode
System
Maintenance
General 9700 Service technician
telephone number
0 32 digits SYS A telephone number can be entered up to 32 digits.
Use the [MONITOR/PAUSE] button to enter a hyphen(-).
11
08 Setting
mode
System User
interface
9702 Automatic
calibration
disclosure level
1 0-2 SYS Sets the disclosing level of automatic calibration.
0: Service technician
1: Administrator
2: User
1
08 Setting
Mode
System
Maintenance
General 9703 Error history
display
- - SYS Displays the latest 20 errors data 2
08 Setting
mode
System Network Scanning 9709 Default data saving
directoryof“Scan
to File”
0 0-2 SYS 0:Localdirectory
1: REMOTE 1
2: REMOTE 2
1
08 Setting
Mode
System
Maintenance
RDMS General 9710 Remote-controlled
service function
2 0-2 SYS 0:Valid(Remote-controlledserver)
1:Valid(L2)
2: Invalid
1
08 Setting
Mode
System
Maintenance
RDMS HTTP 9711 Remote-controlled
serviceURL
setting
- - SYS Maximum 256 letters 11
08 Setting
Mode
System
Maintenance
RDMS HTTP 9715 Initially-registered
serverURLsetting
Refer to
contents
- SYS Maximum 256 letters
<Default value>
https://device.mfp-
support.com:443/device/firstregist.ashx
11
08 Setting
mode
System
Maintenance
(Remote)
RDMS 9718 Short time interval
setting of recovery
from Emergency
Mode
24 1-48 SYS Sets the time interval to recover from the Emergency
Mode to the Normal Mode. (Unit: Hour)
1