Pin No.
XY Z
Signal Input/Output Signal Input/Output
1 XY-IN+ Input Z-IN+ Input
2 XY-OUT+ Output Z-OUT+ Output
3 NC - NC -
4 NC - NC -
5 NC - NC -
6 XY-IN- Input Z-IN- Input
7 XY-OUT- Output Z-OUT- Output
8 NC - NC -
9 NC - NC -
10 NC - NC -
11 NC - NC -
12 NC - NC -
13 NC - NC -
14 NC - NC -
15 NC - NC -
Shell Shield Shield
Dedicated Cable
The dedicated cable for wiring to the Galvo Scanner connector is provided as an option.
The Galvo Scanner connection side has discrete wires.
Perform wiring to match the Galvo Scanner specifications.
The cable model is as shown below.
Type Model Length
For Galvo Scanner CK3W-CAG03A 3 m
Shield
3000 35
24AWG × 6 Pairs
6
1
5
10
15
11
5 Wiring
5-47
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
5-7 Laser Interface Unit
5