Description Cause Corrective action
DA output, DirectPWM
output and encoder pow-
er supply fromCK3W-AX
Unitnot output
Power Supply Unit other than
CK3W-PD048 is being used.
Check the Power Supply Unit model.
CK3W
-AX Unit failure Replace the CK3W-AX Unit.
Internal 24 V power is not be-
ing input to the CK3W-AX Unit
due to a failure of the Unit to its
left.
Replace the Unit to the left of this Unit.
Position data for encoder
connected toCK3W
-AX
Unitnot converted cor-
rectly
The wiring is incorrect. Check that the wiring is correct.
The connected device is faulty. Replace the connected device.
The settings are incorrect. Correct the settings.
Input waveforms are not within
the specified range.
Review the connected device and wiring so that
input waveforms are within the specified range.
The frequency of the input sig-
nal is not within the specified
range.
Adjust the frequency to within the specified range.
CK3W-AX Unitfailure Replace theCK3W-AX Unit.
Analog values from
CK3W
-AD Unit not con-
verted correctly
The wiring is incorrect.
Check that the wiring is correct.
Power Supply Unit other than
CK3W-PD048 is being used.
Check the Power Supply Unit model.
CK3W
-AD Unit failure Replace the CK3W-AD Unit.
Internal 24 V power is not be-
ing input to the CK3W-AD Unit
due to a failure of a Unit to its
left.
Replace the Unit to the left of this Unit.
Position data for encoder
connected to CK3W-ECS
Unit not converted cor-
rectly
The wiring is incorrect.
Check that the wiring is correct.
The settings are incorrect. Correct the settings.
The cable is out of specifica-
tion.
Make sure that the followings are within specifica-
tions.
Length
Wire type (twisted-pair and shielded)
The connected device is faulty. Replace the connected device.
The cable is broken. Replace the cable.
An internal memory error has
occurred.
When Gate3[i].Chan[0].Status[26] is 1, this is a
temporary error in the internal memory
. Cycle the
power supply
.
CK3W-ECS Unit failure Replace the CK3W-ECS Unit.
Internal 24 V power is not be-
ing input to the CK3W-ECS
Unit due to a failure of a Unit to
its left.
Replace the Unit to the left of this Unit.
Position and ON/OFF of
laser connected to
CK3W-GC Unit not oper-
ating correctly
The wiring is incorrect.
Check that the wiring is correct.
The settings are incorrect. Correct the settings.
The cable is out of specifica-
tion.
Make sure that the followings are within specifica-
tions.
Length
Wire type (twisted-pair and shielded)
The connected device is faulty.
Replace the connected device.
The cable is broken. Replace the cable.
6 Troubleshooting
6-8
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)

Table of Contents

Other manuals for Omron CK3W-GC 00 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CK3W-GC 00 Series and is the answer not in the manual?

Omron CK3W-GC 00 Series Specifications

General IconGeneral
BrandOmron
ModelCK3W-GC 00 Series
CategoryController
LanguageEnglish

Related product manuals