EasyManua.ls Logo

Omron NX102-12 Series

Omron NX102-12 Series
578 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model after
change
CS1W
-EIP21
CJ1W
-EIP21
CJ1W
-EIP21
(CJ2)
CJ2B-
EIP21
CJ1W
-EIP21
(NJ)
CJ2M
NJ501-££££
NJ301-££££
NJ101
NX701 NX102 NX1P2
Model
before
change
CIP
Rev
Rev2 Rev3 Rev3 Rev3 Rev3 Rev3
Rev1
*1
Rev2
*2
Rev2 Rev 2 Rev2
CJ1W-
EIP21
Rev3
Yes
---
Yes Yes r5 r3 r4/5 r4/5
No No No
CJ1W-
EIP21
(CJ2)
Rev3
r1 r1
---
Yes r5 r3 r4/5 r4/5 r5 r4/5 r4/5
CJ2B-
EIP21
Rev3
r1 r1 Yes
---
r5 r3 r4/5 r4/5 r5 r4/5 r4/5
CJ1W-
EIP21
(NJ)
Rev3
r1/2 r1/2 r2 r2
---
r2/6 r4 r4 Yes r4 r4
CJ2M Rev3
r1 r1 Yes Yes r5
---
r4/5 r4/5 r5 r4/5 r4/5
NJ501-£
£££
NJ301-£
£££
NJ101
Rev1
r1/2 r1/2 r2 r2 Yes r2/6
---
Yes
No No No
Rev2
r1/2 r1/2 r2 r2 Yes r2/6 Yes
---
Yes r4 r4
NX701 Rev2 No No
r2 r2 Yes r2/6
No
r4
---
r4 r4
NX102 Rev 2 No No
r2 r2 Yes r2/6
No
Yes Yes
---
r4
NX1P2 Rev2 No No
r2 r2 Yes r2/6
No
Yes Yes Yes
---
*1. CPU Unit with a unit version 1.00 to 1.02
*2. CPU Unit with a unit version 1.03 or later
Yes
Can be changed.
No: Cannot be changed.
r1
Cannot be changed if a network variable is specified as a tag.
r2
Cannot be changed if the maximum size of a tag name or tag set name (size after conversion into
UTF-8) exceeds 48 bytes.
r3
Cannot be changed if the following items exceed the permissible settings of the device after the
change:
Number of I/O connections, number of tags, number of tag sets, and size of one tag set.
r4
Cannot be changed in any of the following cases:
The number of I/O connections, number of tags, number of tag sets, or size of one tag set ex-
ceeds the permissible settings for the device after the change.
RPI exceeds the permissible settings or is set in 0.5-ms increments (such as 10.5ms)
r5
Cannot be changed if a tag set size is an odd number of bytes.
r6
Cannot be changed if tags, tag sets, or refreshing sizes exceed the permissible settings.
7-2-18
Displaying Device Status
Device status is displayed using the following icons in Maintenance Mode.
T
o enter Maintenance Mode, select Large Icons - Maintenance Mode from the View Menu.
7 Tag Data Link Functions
7-78
NJ/NX-series CPU Unit Built-in EtherNet/IP Port Users Manual (W506)

Table of Contents

Related product manuals