12.10 o: KEYPAD
820 SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
No. Item
Number of
Characters
Description
5 Monitor Unit 1
*2
4 Unit code and number of decimal places used for the monitor selected with o5-03
Example when U1-01 = 30.00 Hz:
Number of decimal places = 2, Hz unit code = 01, monitor unit 1 = 0201 (Hex.)
6 Monitor number 2 4 Monitor number (Dec.) selected by o5-04 [Log Mon Data 2]
7 Monitor Unit 2 4 Unit code and number of decimal places used for the monitor selected with o5-04
: : : :
22 Monitor number 10 4 Monitor number (Dec.) selected by o5-12 [Log Mon Data 10]
23 Monitor Unit 10 4 Unit code and number of decimal places used for the monitor selected with o5-12
24 to 27 Reserved 4 -
28 Row number 6 Row number (Hex.) in the data log file
*1 If there is no data log monitor selected, the text string of [0000] is generated.
*2 Refer to Table 12.60 for information about unit codes.
Table 12.60 Unit Codes
Unit Code (Hex.) Unit Unit Code (Hex.) Unit Unit Code (Hex.) Unit Unit Code (Hex.) Unit
00 08 PPR 10 H 18 0H
01 Hz 09 kW 11 V 19
02 RPM 0A Ω 12 us 1A
03 % 0B ms 13 min 1B
04 VAC 0C kHz 14 °C 1C
05 VDC 0D PSI 15 W 1D
06 A 0E MPM 16 kWH 1E
07 sec 0F FPM 17 MWH 1F
Third and Subsequent Rows: Log Data
This example shows the data text strings and data generated for the third row of log data.
Example of generated data:
02,0012,160107111239,1770,1770,00BE,0118,0028,0000,0000,0000,0000,0000,0000,0000,00000C
No. Item
Number of
Characters
Description
1 Attribute 2 [02] shows that the record is a monitor data record.
2 File number 4 The [xxx] part of the [Q0xxx.csv] filename is a 3-digit decimal number in hexadecimal format.
3 Time stamp 12 Data log data was retrieved (YYMMDDHHMMSS)
4 Log Monitor Data 1 4 Log monitor data (Hex.) of the monitor selected with o5-03 [Log Mon Data 1]
5 Log Monitor Data 2 4 Log monitor data (Hex.) of the monitor selected with o5-04 [Log Mon Data 2]
: : : :
13 Log Monitor Data 10 4 Log monitor data (Hex.) of the monitor selected with o5-12 [Log Mon Data 10]
14 Reserved 4 -
15 Encoding data 4 Encoding data for log monitor data 1 through 10 (Hex.)
Bits 0 through 9 show the encoding of log monitor data 1 1 through 10. A bit value of 1 shows that the data represents
a negative value. (Log monitor data 1 through 10 is absolute value data without encoding)
Example when log monitor data 2, 5, and 8 show negative values: Bits 1, 4, and 7 have values of 1, and the encoding
data = 0010010010 (Bin.) = 0092 (Hex.)
16 Row number 6 Row number (Hex.) in the data log file
o5-01 Log Start Selection
No.
(Hex.)
Name Description
Default
(Range)
o5-01
(1551)
RUN
Log Start Selection
Sets the data log function. This parameter is only available on an LCD keypad.
0
(0 - 1)
0 : OFF

Table of Contents

Other manuals for Omron Q2A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron Q2A Series and is the answer not in the manual?

Omron Q2A Series Specifications

General IconGeneral
BrandOmron
ModelQ2A Series
CategoryController
LanguageEnglish

Related product manuals